Leighton Home Page
ServicesProjectsCareersNewsAboutContact  
         
   
   

News Room


^ back to top ^

10/06/2009
October 2009: Vincent Ip, GE - Joins Leighton

Vincent Ip has joined Leighton's Los Angeles office as Managing Director.  Vincent will build on his 25 years of consulting experience providing solutions for public and commercial clients. Vincent is a well-rounded consultant, bringing both technical expertise and interpersonal skills to collaborate well with the client's team, enabling the team to design and implement valuable solutions that exceed client expectations.

His expertise in ground improvements, design-build, and geo-environmental will provide further strength in the public sector and commercial markets. Vincent is a registered geotechnical engineer with expertise from design through construction.

^ back to top ^

09/17/2009
September 2009: Leighton receives contract from Los Angeles Department of Water and Power
This multi-year award is to provide geotechnical services for projects and programs located throughout and in the vicinity of the City of Los Angeles, the First and Second Los Angeles Aqueducts, the Owens Valley, and the Mono Basin.  Projects are primarily a part of the Water System Capital Improvement Program (CIP) which includes developing and improving water tanks, reservoirs, pumping stations, trunk lines, tunnels, district yards and buildings, water supply facilities, water treatment facilities, regulator stations, and other system and support facilities

 



^ back to top ^

03/15/2009
March 2009: Santa Ana River Interceptor (SARI) Line Relocation

Leighton begins the geotechnical exploration and Initial Site Assessment for the Santa Ana River Interceptor (SARI) Line Relocation between Prado Dam and Weir Canyon Road.

The SARI Line is a regional sanitary sewer line that conveys raw sewage and brine (wastewater from agriculture, commercial and other sources) from the Inland Empire and Orange County to the Orange County Sanitation District (OCSD) treatment plant in Fountain Valley.

Leighton’s field exploration will include more than 60 borings, and installation of groundwater monitoring wells. The use of electrical resistivity imaging (ERI) will be used to evaluate the location of the Whittier and Whittier-Elsinore faults. Four electrical resistivity lines will range in length between 550 and 1,100 feet. This process is a non-destructive geophysical technique for imaging subsurface structures from electrical measurements by means of injection of DC current in the ground, measuring the voltage drops produced at points on the surface and mapping the subsurface distribution of electrical resistivity. The electrical resistivity values are digitally recorded on the Sting meter and processed using specialized software to build a three-dimensional model of a site which can be used to evaluate existing void spaces, depth of conductive materials, and approximate volumes of conductive objects within the subsurface soils. This subsurface information along with the available geological data of the site will be used to interpret the potential of faults crossing the SARI Line alignment.

Constructed as a joint project of OCSD and the Santa Ana Watershed Project Authority in the early 1970s, the SARI Line was originally buried about 20 feet below the river bed. Over time, the soil cover over the SARI Line between Weir Canyon Road and Prado Dam has experienced heavy erosion and the pipeline is exposed at some locations. The probability of damage to the SARI Line is expected to be higher when Prado Dam’s planned maximum controlled release increases from 10,000 to 30,000 cubic feet per second as part of the Santa Ana River Mainstem Project (SARMP) improvements. The Orange County Flood Control District is the local sponsor of the SARMP and is responsible through its Local Cooperative Agreement with the U.S. Army Corps of Engineers to mitigate the impacts of Prado Dam improvements on existing utilities such as the SARI Line.

^ back to top ^


  Leighton News
 

© 2008 Leighton Group, Inc. All Rights Reserved Privacy Policy